IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

874

matching recommendations
Reset
ARC 2.212 Condensate
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0340 # 04 Y:2006 04 2006 INSULATE FEEDWATER TANK $879 $220 Implemented
UD0750 # 06 Y:2006 06 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $44,000 $25,000 Implemented
NC0342 # 07 Y:2006 07 2006 INSULATE FEEDWATER TANK $676 $1,087 Not Implemented
LE0239 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $392,390 $95,000 Not Implemented
LE0239 # 03 Y:2006 03 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $204,235 $200,000 Not Implemented
UD0743 # 09 Y:2006 09 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $17,000 $0 Implemented
LL0256 # 02 Y:2006 02 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $111,471 $70,939 Implemented
OR0501 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $119,000 $200 Implemented
LM0120 # 03 Y:2006 03 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $50,309 $1,000 Implemented
NC0339 # 04 Y:2006 04 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $93,691 $100,000 Implemented
LL0255 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $76,757 $77,280 Not Implemented
SU0235 # 08 Y:2006 08 2006 INSULATE FEEDWATER TANK $3,650 $720 Implemented
WV0342 # 03 Y:2006 03 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $103,142 $100,000 Implemented
AM0508 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $8,400 $2,190 Not Implemented
NC0336 # 05 Y:2006 05 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $12,198 $7,290 Implemented
NC0334 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $12,388 $7,290 Not Implemented
LL0244 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $490,346 $849,320 Not Implemented
UD0736 # 08 Y:2006 08 2006 INSULATE FEEDWATER TANK $12,187 $6,825 Implemented
NC0332 # 04 Y:2006 04 2006 INSULATE FEEDWATER TANK $389 $277 Not Implemented
GT0816 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $15,818 $4,500 Implemented
IC0111 # 04 Y:2006 04 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $93,000 $235,998 Implemented
CO0580 # 04 Y:2006 04 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $3,750 $12,850 Implemented
NC0325 # 01 Y:2005 01 2005 INCREASE AMOUNT OF CONDENSATE RETURNED $27,917 $25,000 Not Implemented
OR0491 # 05 Y:2005 05 2005 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $730 $1,300 Not Implemented
IC0109 # 06 Y:2005 06 2005 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $37,809 $131,160 Not Implemented